home *** CD-ROM | disk | FTP | other *** search
/ Eagles Nest BBS 1 / Eagles_Nest_Mac_Collection_Disc_1.TOAST / Apple Menu Items / TelebitHelp / Telebit T2500 Help.rsrc / TEXT_-15680_Telebit T2500 Help.txt < prev    next >
Text File  |  1992-06-22  |  18KB  |  383 lines

  1.  
  2.         ‚Ä¢‚Ä¢‚Ä¢ Telebit T2500 Extended Mode Quick-Help v1.01 ‚Ä¢‚Ä¢‚Ä¢
  3.  
  4. ‚Ä¢COMMAND SUMMARY:::::
  5. (A/B/C... reflect 0/1/2...)
  6.  
  7. ATA-Answer Phone       A/-Repeat Prev. Cmd.    ATC-Carrier on=1
  8. ATD-Dial Number        ATE-Echo on=1           ATF-EchoPlex on=1
  9. ATG-Go to Voice        ATH-Phone Hook on=0     ATI-Info 4=Registers
  10. ATM-Spkr on dialing=1  ATN=/?-Set/Read # Dir.  ATO-Online
  11. ATQ-Quiet Enable       ATS=/?-Set/Read S Reg   ATV-Verbose OFF/ON        
  12. ATW-Prog. Rpt.OFF/ON   ATX-Result Codes        ATY-Disc. on Brk N/Y
  13. ATZ Resets NV Memory
  14.  
  15. ATD modifiers:
  16. W-Wait for Dial Tone   N-Ref # in # Dir.       P-Pulse DIaling
  17. T-Tone Dialing         ,-Timed Wait            |-On-hook flash
  18. @-Wait for Quiet Ans.  R-->Ans. Mode on Ans.   ;-Cmd mode after dial
  19. \-Ref. a # In # Dir.
  20.  
  21. ATX modifiers:
  22. 0-Basic Result Codes  1-Extended  2-MNP 3-MNP/PEP 10-14-Conventional
  23.  
  24.  
  25. AT&B-Blind Command              AT&E-Use EEProm Param. DEFAULT/A/B
  26. AT&F-Recall Factory Param.      AT&N-Display EEProm DEFAULT/A/B
  27. AT&P-US/UK Pulse Dialing
  28. AT&R-Forced Retrain/Renegotiate
  29. AT&T-Initiate test Function
  30. AT&W-Write Configuration Parameters to EEProm DEFAULT/A/B
  31. AT%-Remote Modem Access
  32.  
  33.  
  34. ‚Ä¢REGISTER SUMMARY:::
  35.  
  36. S #      RANGE  DESCRIPTION                                 DEFUALT
  37. -------------------------------------------------------------------
  38. S0      0-255   Answer on Ring                            0=pc1=sa,rm
  39. S1      0-255   Count of Rings          
  40. S2      0-255   Escape Character (ASCII)                       43
  41. S3      0-255   Carriage Return Character (ASCII)              13
  42. S4      0-255   Line Feed Character (ASCII)                    10
  43. S5      0-255   Backspace Character (ASCII)                     8
  44. S6      2-255   Dial Tone Wait Time (seconds)                   2
  45. S7      1-255   Wait for Carrier Time (seconds)                40
  46. S8      0-255   Pulse Time for Comma (seconds)                  2
  47. S9      1-255   Carrier Detect Time (100 ms)                    6
  48. S10     1-255   Carrier Loss Time Till Disconnect (100 ms)      7
  49. S11     50-255  Touch Tone Timing (ms)                         70
  50. S12     0-255   Escape Sequence Guard Time (1/50 sec units)    50
  51. S18     0-255   Test Termination Timer                          0
  52. S25     0-255   DTR Delay Timing (10 ms)                        5
  53. S26     0-255   RTS to CTS Delay Interval (100 ms)              1
  54. S38     0-255   Delay Before Disconnecting                      0
  55. S41     0-255   Inactivity Timer (tenths of hours)              0
  56. S45     0,255   Remote Access(0=Disable, 255=Enable)            0
  57. S47     0 or1   DSR Delay Time (50 ms units)                    4
  58. S48     0 or1   Eight Bit Compare (Lower Seven/All Eight)       0
  59. S49     0 or1   Product ID IO Return (96X code/123 code)        0
  60. S50     0..255  Transmission Mode                               0
  61.         0=      Auto Speed Determination
  62.         1=      300bps (Bell 103 or V.21)
  63.         2=      1200bps (Bell 212A or V.22)
  64.         3=      2400bps (V.22bis)
  65.         4=      300 bps (V.21)
  66.         5=      1200/75 bps (V.23)
  67.         6=      9600 bps (V.32)
  68.         254=    Use last AT command speed
  69.         255=    PEP 19200 bps
  70. S51     0..255  Interface Speed                                 4
  71.         0=      300bps
  72.         1=      1200bps
  73.         2=      2400bps
  74.         3=      4800bps
  75.         4=      9600bps
  76.         5=      19200bps
  77.         252=    AutoBaud (no type-ahead)
  78.         254=    AutoBaud (19200 bps default)
  79.         255=    AutoBaud (9600 bps default)
  80. S52     0-2     DTR Interpretation                           0sa,rm,1pc
  81.         0=      DTR ignored
  82.         1=      DTR used for the PC (disconnect and disable auto ans
  83.                   if DTR not present)
  84.         2=      DTR used for the Mac (disconnect and reload optg para
  85.                   if DTR dropped; no auto ans if DTR not present)
  86.         3=      Enter command mode when DTR dropped
  87.         4=      Hang up and enter command mode when DTR dropped
  88. S54     0-4     Break Signal Interpretation                      0
  89.         0=      Switch to command mode
  90.         2=      Send immediate break to remote DTE
  91.         3=      Send bread to DTE in sequence with data stream if in
  92.                    data mode; send immediate break if in cmd mode
  93.         4=      Discard break signal
  94. S55     0-3     Escape Character (ex:+)/Sequence (+++) Interp.    0
  95.         0=      Go to command mode; pass escape char to remote DTE
  96.         1=      Discard buffer data, pass escape character
  97.         2=      Send escape char to remote DTE immediately
  98.         3=      Send escape char to remote DTE in data stream
  99. S56     0-255   XON Character (ASCII)                           17
  100. S57     0-255   XOFF Character (ASCII)                          19
  101. S58     0-7     Flow Control Used by DTE                         3
  102.         0=      No Flow Control (not recommended)
  103.         1=      RTS/CTS in Half Duplex
  104.         2=      RTS/CTS in Full Duplex
  105.         3=      Use XON/XOFF
  106.         4=      Use XON/XOFF and RTS/CTS
  107.         5=      Use ENQ/ACK
  108.         6=      Use ENQ/ACK and XON/XOFF
  109.         7=      Use transparent XON/XOFF  (Set S68 to 255)
  110. S59     0=255   Prompt Character (ASCII)                         0
  111. S61     0-255   Speaker Volume                                 150
  112. S62     2-255   Break Length Time (50 ms)                        3
  113. S63     0-2     Commmand Mode Selection                          1
  114.         0=      AT not allowed; enhanced command mode
  115.         1=      AT required; enhanced command mode
  116.         2=      AT required; conventional command mode
  117.                   (To enter enhanced from conventional, AT~S63=n
  118. S64     0 or1   Dial/Answer Abort Sequence                       0
  119.         0=      Abort if char trans by local DTE before connect
  120.         1=      Ignore char sent by local DTE while dial or ans.
  121. S65     0 or1   XON/XOFF Failsafe (0=normal)                     0
  122. S66     0-2     Lock Interface Speed                             0
  123.         0=      Change speed to match connection, no flow
  124.         1=      Lock Speed, use flow control in V.32 or low speed
  125.         2=      as 1 if MNP connection established.
  126. S67     0-2     CTS Interpretation (if S58=1, S67 ignored)       0
  127.         0=      If full dup. RTS/CTS, CTS as in S68; otherwise on
  128.         1=      CTS off until carr. det.  On after RTS, then as 0
  129.         2=      CTS on after RTS OFF to ON; delay as S26
  130. S68     0..255  Flow Control Used by DCE                       255
  131.         0=      No Flow Control
  132.         2=      Use CTS flow control in full duplex mode
  133.         3=      Use XON/XOFF
  134.         4=      Use both XON/XOFF and CTS Flow Control
  135.         5=      Use ENQ/ACK
  136.         6=      Use both ENQ/ACK and XON/XOFF 
  137.         255=    Use flow control specified in S58
  138. S69     0-2     XON Signal Handling                               0
  139.         0=      XON processed by modem; not passed to remote
  140.         1=      XON processed and passed on
  141.         2=      If modem XOFFed, XON proc., not passed; else pass 
  142. S70-S78 cannot be set by user; S70-S76 PEP information
  143. S70             Instantaneous Transmit Rate (send baud rate)
  144. S71             Transmit Bits per Channel
  145. S72             Instantaneous Receive Rate (receive baud rate)
  146. S73             Receive Bits per Channel
  147. S74             Received Packets Retransmitted
  148. S75             Packets Accepted
  149. S76             Equivalent Line Noise Profile
  150. S77             Frequency Offset
  151. S78     0-100   Slow or V.32 Mode Line Quality (>50 o.k.)
  152. S90     0 or1   Bell/CCITT mode                                   0
  153. S91     0-2     Gaurd Tone Selection                              0
  154.         0=      No Guard Tone
  155.         1=      1800 Hz guard tone
  156.         2=      550 Hz guard tone
  157. S92     0-2     Answering Sequence Selection                      0
  158.         0=      Normal search sequence (See S50 description)
  159.         1=      PEP 19200 Answer Tones Last
  160.         2=      Normal search sequence with 3 sec. v.25 tone first
  161. S93     3-255   V.32 AC Transmit Duration (100 ms)                8
  162. S94     0-3     Transmission Speed Negotiation                    1
  163.         0=      Fallback disabled; connect as S50
  164.         1=      Connect nego. up to S50 max, starting high
  165.         2=      Fallback within specified modulation scheme only
  166.         3=      Use appropriate fallback exclusively
  167. S95     0-2     MNP Operating Mode                                0
  168.         0=      Normal mode (MNP disabled)
  169.         1=      MNP reliable mode (if no MNP no CONNECT)
  170.         2=      MNP auto reliable mode (if no MNP, fallback)
  171. S96     0-1     MNP Data COmpression Disable/Enable               1
  172. S100    0 or1   Normal/Reverse Answer/Originate Mode              0
  173. S101    0-4     Continuous Answer/Orginate Mode (0 normal)        0
  174. S102    0-2     Auxiliary Telco Lead Setting (RackMount)          0
  175. S104    0-2     Automatic Dialing Options                         0
  176. S105    0-2     T/D Switch Disable/Enable/Enable on-hook          1
  177. S110    0,1,255 Data Compression Enable                         255
  178.         0=      Disable Data Compression
  179.         1=      Enable Data Compr. if PEP conn & remote comp. on
  180.         255=    Enable if PEP conn & remote set to S110=1
  181. S111    0-255   File Transfer Protocol Support                  255
  182.          0=     No Protocol supported
  183.         10=     Kermit with no parity
  184.         11=     Kermit with odd parity
  185.         12=     Kermit with even parity
  186.         13=     Kermit with mark parity
  187.         14=     Kermit with space parity
  188.         20=     Xmodem/Ymodem support
  189.         30=     UUCP  "g" protocol
  190.        255=     Use protocol specified by remote modem
  191.                 (Note: only valid with the PEP 19200 connection)
  192. S112    0-127   Kermit Mark Character (ASCII)                     1
  193. S121    0 or1   Echo Suppressor Compensation OFF/ON               0
  194. S130    0-5     DSR Interpretation                                2
  195.         0=      Always on
  196.         1=      On when answer tone
  197.         2=      On when modem ready for commands or data
  198.         3=      As 2 and off for S47 interval on carrier lost
  199.         4=      On when modem off-hook
  200.         5=      On only when carrier from remote modem
  201. S131    0-3     DCD Interpretation                                2
  202.         0=      Always on
  203.         1=      On when carrier from remote modem
  204.         2=      On when modem ready for commands or data
  205.         3=      As 2 and off for S47 interval when carrier lost
  206. S150    0-2     Asynchronous/Synchronous mode selection           0
  207.         0=      Asynchronous
  208.         1=      PEP SDLC
  209.         2=      Transparent Synchronous
  210. S151    1-5     SDLC Interface Speed                              4
  211.         1=      1200 bps
  212.         2=      2400 bps
  213.         3=      4800 bps
  214.         4=      9600 bps
  215.         5=      19200 bps
  216. S152    0-2     SDLC Switched/Nonswitched                         1
  217.         (S152 is interpretation of DSR; S52 of DTR)
  218.         0=      Non-switched; DSR active--modem ready for local DTE
  219.         1=      Switched; DSR off til DTR on and PEP link w/remote
  220.         2=      Special switched; DSR active--modem rdy for lcl DTE
  221. S153    0-1     SDLC Full/Half Duplex Mode                        1
  222. S154    0-2     Synchronous Clock                                 0
  223.         0=      Modem pins 15/17 used to control data streams
  224.         1=      Local DTE pin 24 used
  225.         2=      DCE control, pin 15, derived from incoming carrier
  226. S155    0-1     NRZ/NRZI Data Encoding                            1
  227. S160-S164--fine tuning SDLC protocol support.  Reccomend defaults
  228. S222    0-127   Enhanced Command Mode Access Character (ASCII)  126
  229. S255    0-2     Default Profile (A-B Switch/A/B); &F doesn't change
  230.  
  231.  
  232.  
  233.  
  234. ‚Ä¢RESULT CODES:::
  235.  
  236. #     Message and Description
  237. ------------------------------------------------------
  238. 0     OK--The command was successfully completed.
  239. 1     CONNECT 300--Connected at 300 baud.
  240. 2     RING--An incomming ring was detected.
  241. 3     NO CARRIER--Carrier lost or not available.
  242. 4     ERROR--A command error has been encountered.
  243. 5     CONNECT 1200--Connected at 1200 baud
  244. 6     NO DAIL TONE--No dail tone was detected.
  245. 7     BUSY--Remote connection is busy (Again, sh_it!)
  246. 8     NO ANSWER--The remote connection did not answer.
  247. 10    CONNECT 2400--Connected at 2400 baud.
  248. 11    CONNECT 4800--Connected at 4800 baud.
  249. 12    CONNECT 9600--Connected at 9600 baud.
  250. 20    CONNECT 300/REL--MNP connection at 300 baud.
  251. 22    CONNECT 1200/REL--MNP connection at 1200 baud.
  252. 23    CONNECT 2400/REL--MNP connection at 2400 baud.
  253. 24    CONNECT 4800/REL--MNP connection at 4800 baud.
  254. 25    CONNECT 9600/REL--MNP connection at 9600 baud.
  255. 50    CONNECT FAST--Connected established with PEP (19200)
  256. 52    RRING--Remote connection is ringing.
  257. 61    CONNECT FAST/KERM--PEP with Kermit support
  258. 62    CONNECT FAST/XMDM--PEP with X/YModem support.
  259. 63    CONNECT FAST/UUCP--PEP with UUCP support.
  260. 70    CONNECT FAST/COMP--PEP connection with data compression
  261. 71    CONNECT FAST/KERM/COMP--as 70 with Kermit support
  262. 72    CONNECT FAST/XMODEM/COMP--as 70 with Xmodem support
  263. 73    CONNECT FAST/UUCP/COMP--as 70 with UUCP support
  264.  
  265. A key issue is using the Telebit with both Microphone and other
  266. software.  The way I do this is to have the Telebit set to detect the
  267. Mac interface setting with any particular program (S51=252).  It does so
  268. each time it sees an AT.  To prevent any default to a "wrong" speed, I
  269. use 252, which has the disadvantage of not permitting type-ahead.  This
  270. hasn't been a problem so far.  In my microphone setup scripts I listen
  271. for AT and ok before issuing another AT line; in other scripts I only
  272. need one AT line; in other modem programs there doesn't seem to be any
  273. problem.
  274.  
  275. I then allow the Telebit to decide what speed it's connected at, but not
  276. change the Mac interface speed (S66=1).  This also allows setting such
  277. programs as Compuserve Navigator to 9600 baud, connecting at 2400 with
  278. MNP, and getting faster than 2400 effectively due to the decompression
  279. of MNP.  I have Microphone set to 19200, Navigator and MacNet set to
  280. 9600, connect Macnet at 9600, Nav at 2400, AppleLink at 2400, MCIMail at
  281. 2400, and it all works. Microphone also connects fine to lower speed
  282. modems this way, while preserving the interface speed.
  283.  
  284. Second, it is important to set factory defaults (AT~&F) after starting,
  285. both so you know what condition the modem is in and to save having to
  286. set some defaults to what is already the default value.  Note the
  287. "tilde" after the AT to make sure the Telebit starts out in enhanced
  288. default factory settings mode.
  289.  
  290. Telebit default settings (do AT~&F; set; do AT&W) for independently
  291. synchronizing modem with AT commands sent from communication programs,
  292. and synchronizing modem to modem speeds (permits setting Navigator to
  293. 9600 and connecting at 2400 MNP, for example.)  Is set for XON/XOFF
  294. handshaking.  On entering Microphone or other program with hardware
  295. handshaking set, set S58 to 2; on leaving do ATZ.  On dialing PEP
  296. modems, set S50 to 255, others set to 0; On leaving program using PEP
  297. speed or hardware handshaking do ATZ:
  298.  
  299. ATN?
  300. E1 F1 M1 Q0 P V1 W0 X3 Y0 &P0 &T4     Version GA1.00
  301. S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07:090 S08=002
  302. S09=006 S10=007 S11=070 S12=050 S18=000 S25=005 S38=000 S41=000 S45=000
  303. S47=004 S48:001 S49=000 S50=000 S51:252 S52=000         S54=000 S55=000
  304. S56=017 S57=019 S58=003 S59=000 S60=000 S61=150 S62=003 S63=001 S64=000
  305. S65=000 S66:001 S67=000 S68=255 S69=000 S90=000 S91=000 S92=000 S93=008
  306. S94=001 S95:002 S96=001 S100=000 S101=000 S102=000 S104=000 S105=001
  307. S110=255 S111:020 S112=001 S121=000 S130=002 S131=002 S255=000
  308. N0:
  309. N1:
  310. N2:
  311. N3:
  312. N4:
  313. N5:
  314. N6:
  315. N7:
  316. N8:
  317. N9:
  318. OK
  319.  
  320. Sample Microphone Settings Script (don't break lines w/returns):
  321.  Settings File = Telebit Setup
  322.  Script Name = **setup mdm
  323.  Command Key = 
  324.  F-Key = 
  325.  Menu = YES
  326.  Button = NO
  327.  Version = 3006
  328.  System = Macintosh
  329.  
  330. 1   Set Variable * PROTOCOL from Dialog Box "'IF using Xon/Xoff enter
  331.       YES. IF hardware handshake is used, then NO.'"
  332. 2   Set Variable * PROTOCOL from Expression "UCASE(PROTOCOL)"
  333. 3   If Expression "protocol='NO'"
  334. 4    Alert * OK "'Make sure your modem cable is wired correctly. 
  335.         A standard cable may not be.'"
  336. 5    Alert * OK/Abort "'The modem will stop responding if incorrect
  337.        cable is used.  If so, Abort now!'"
  338. 6   Else
  339. 7    Alert * OK "'You *MUST* use the ''*send file'' command on the
  340.        script menu.'"
  341. 8   End If
  342. 9   Send Text String "'AT~&F^M'"
  343. 10  Wait Seconds "'2'"
  344. 11  Signal Short Break
  345. 12  Set Comm Param Baud Rate 9600
  346. 13  Send Text String "'AT~&F^M'"
  347. 14  Wait for Line Containing "'AT'"
  348. 15  Wait for Line Containing "'ok'"
  349. 16  Send Text String "'ATSS7=90 S48=1 S51=252^M'"
  350. 17  Wait for Line Containing "'AT'"
  351. 18  Wait for Line Containing "'ok'"
  352. 19  If Expression "protocol='NO'"
  353. 20   Send Text String "'ATS58=2^M'"
  354. 21   Wait for Line Containing "'AT'"
  355. 22   Wait for Line Containing "'ok'"
  356. 23  Else
  357. 24   Send Text String "'ATS58=3^M'"
  358. 25   Wait for Line Containing "'AT'"
  359. 26   Wait for Line Containing "'ok'"
  360. 27  End If
  361. 28  Set Comm Param Baud Rate 19,200
  362. 29  Send Text String "'ATS66=1 S95=2 S111=020^M'"
  363. 30  Wait for Line Containing "'AT'"
  364. 31  Wait for Line Containing "'ok'"
  365. 32  Send Text String "'ATX3^M'"
  366. 33  Wait for Line Containing "'AT'"
  367. 34  Wait for Line Containing "'ok'"
  368. 35  Wait Seconds "'1'"
  369. 36  Send Text String "'AT&W^M'"
  370. 37  Wait for Line Containing "'AT'"
  371. 38  Wait for Line Containing "'ok'"
  372. 39  Wait Seconds "'1'"
  373. 40  Repeat
  374. 41   Send Text String "'AT^M'"
  375. 42   When Line Contains "'OK'"
  376. 43    Leave
  377. 44   Or When Seconds Have Passed "'2'"
  378. 45    Cycle
  379. 46   End When
  380. 47  Until Line Contains "'AT'"